• Skip to primary navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer
Able Power logo
Phone Icon1300 793 001 Store Lopcator IconStore Locator Cart Icon
  • Portable Generators
    • Inverter Petrol Generators
    • Petrol Generators
    • Diesel Air Cooled
    • Diesel Water Cooled
    • MINESPEC Portable
    • Accessories & Parts
  • Diesel Generators
    • Generators 6kVA - 20kVA
    • Generators 21kVA - 55kVA
    • Generators 56kVA - 250kVA
    • Generators 251kVA - 1100kVA
    • Synchronised 660kVA - 2200kVA
    • YANMAR Powered Generators
    • KUBOTA Powered Generators
    • CUMMINS Powered Generators
    • ATS - Mains Failure Box
    • Load Banks
    • Alternators
    • Accessories & Parts
    • Filters
  • Renewable Energy
        • Able PAK

          • Portable Power Solutions
          • Battery Power Systems
          • Solar Water Pumps
        • Discover

          • Clever Solutions
          • Inside A PAK
          • Diesel Reduction
          • Maximising Renewables
          • Rapid High Power
        • Support Information

          • My Account
          • About Us
          • Privacy Policy
          • Australia Wide Shipping
          • Terms and Conditions
          • Returns and Exchange Policy
          • Inside Story
          • Testimonials
          • Contact Us
        • Portable Power Stations
        • Solar Water Pumps
  • Fuel Tanks
    • Poly Fuel Tanks
    • Single Wall Fuel Tanks
    • Self Bunded Fuel Tanks
    • Accessories & Parts
  • Lighting Towers
  • Air Compressors
    • Piston Compressors
      • Electric
      • Petrol
      • Diesel
    • Screw Air Compressors
      • Electric
      • Petrol
      • Diesel
    • Portable Air Compressors
    • Air Dryers
    • Accessories & Parts
  • Power Equipment
    • Pressure Washers
      • Electric Pressure Washers
      • Petrol Pressure Washers
      • Diesel Pressure Washers
    • Water Pumps
      • Fire Pumps
        • Fire Pumps Petrol
        • Fire Pumps Diesel
      • Transfer Pumps
        • Transfer Pumps Petrol
        • Transfer Pumps Diesel
      • Stainless Steel Pumps
        • Stainless Steel Pumps Petrol
        • Stainless Steel Pumps Diesel
      • Chemical Transfer Pumps
        • Chemical Pumps Petrol
        • Chemical Pumps Diesel
      • Trash Pumps
        • Trash Pumps Petrol
        • Trash Pumps Diesel
      • Submersible Pumps
      • Accessories & Parts
      • Hose & Fittings
      • Petrol Water Pumps
      • Diesel Water Pumps
    • Engines
      • Petrol
      • Diesel
    • Landscaping
    • Concrete Tools
      • Core Drilling Tools
      • Walk Behind Concrete Saws
      • Concrete Mixer & Power Trowel
    • Hose Crimper
  • Plate Compactors
    • Parts
You are here: Home / Renewable Energy / More than $69,000 fuel savings per year with an Able PAK – Example (1)

More than $69,000 fuel savings per year with an Able PAK – Example (1)

8 September, 2024

Able PAK battery power system fuel savings example(1)

Able PAKs provide cost savings at construction sites.

Over 45% reduction in Diesel Generator run time and corresponding fuel savings with Able PAK Battery Power Systems can be realized at construction site offices.

Able PAK 066-066 or Able PAK 100-100 in their Microgrid running modes can deliver cost savings and Scope 1 emission reductions in user cases scenarios such as construction site office complex.

The Results:

  • $69,000 fuel saving per year
  • $24,000 nett savings in two years
  • Less than 2 year payback as a return on investment
  • 85T CO2 emission savings per year

The Scenario:

Consider a construction site using a diesel generator (137kVA) to power a temporary office building complex.    

The power demand load during daylight activities is significantly different to that at night-time, where security lights, fridges and idle power to computers are still drawing a load. 

During the night-time, generators can be severely underloaded with the potential for engine damage being incurred.

Savings are realized by having an Able PAK battery power system, such as a PAK 066-066, in Microgrid Mode, coupled to a smaller generator (Able GEN LG100CS), which provides the load when needed, in a fuel-efficient manner.

Able PAK Microgrid Mode:

This mode is a suitable selection when the total load at any time is less than the selected Able PAK prime power (kW).

In this mode the Able PAK is the primary power supply for the load, and automatically starts and stops the diesel generator only as required to recharge the Able PAK.

The generators start and stops are triggered by a lower and upper State of Charge (SOC) of the Able PAK’s internal Battery Energy Storage System (BESS).

The Microgrid settings to maximise the BESS lifespan are commonly set to SOC 30% as a GEN start, and 85% for GEN stop.  These settings are also adjustable to best suit the scenario and circumstances on hand.

The generator then only runs when needed to, at an optimum load setting, which is also a programable function within the Able PAK Energy Management System (EMS).

The selected sizing of the smaller generator is such that it provides a timely recharging of the Able PAK, which can be up to 60kW of continuous power output.

Benefits of the Able PAK Battery Power System:

  • Cost savings
  • Reduced diesel fuel wastage on oversized generators
  • Reduced generator damage from underloading
  • Extend generator lifespan and service intervals.
  • Reduced Scope 1 CO2 emissions
  • Reduced noise pollution

An even further reduction in diesel consumption can be realized if coupled with a roof-top solar PV system … see the Inside Story Example 3 …

Please contact Able Sales on 1300 793 001 to discuss your application and how we can help you save money with an Able PAK.

We welcome the opportunity to demonstrate the Able PAK potential with simulations using our Able PAK, GEN and load banks.

More posts like this

Previous Post: « Generator Paralleling VS. Synchronised Generators
Next Post: More than 43% reduction in diesel per year with an Able PAK – Example (2) »

Primary Sidebar

Recent Posts

  • Solar or Diesel Lighting Towers: Which is Right for You?
  • $84,000 net savings in 2 years with an Able PAK plus Solar PV – Example (3)
  • More than 43% reduction in diesel per year with an Able PAK – Example (2)
  • More than $69,000 fuel savings per year with an Able PAK – Example (1)
  • Generator Paralleling VS. Synchronised Generators

Categories

  • Crisis Preparation
  • Generators
  • Mine Spec
  • Portable Generators
  • Renewable Energy

Footer

Able Power logo
© 2024 Able Power. All Rights Reserved.

Melbourne

Mon-Fri: 8am-5pm
Saturday: Closed
Unit 5/11 Industrial Ave,
Thomastown VIC 3074
(03) 9302 3602
1300 735 902

Brisbane

Mon-Fri: 8am-5pm
Saturday: Closed
Unit 1/8 Prosperity Pl
Park Ridge QLD 4125
(07) 9372 9001
1300 735 840

Perth

Mon-Fri: 8am-5pm
Saturday: 8am-12pm
Unit 3 / 41 Tate St,
Bentley WA 6102
(08) 9358 2299
1300 735 001
angle graphic